Current Affairs updated daily
KalviGavaniKalviGavani
Class 11 · CBSE

Class 11 Basic Electrical Engineering Exercise Solutions

Class 11 Basic Electrical Engineering exercise solutions — electric circuits, Ohm's law, Kirchhoff's laws, magnetism, AC circuits, electrical safety MCQs and answers.

Updated 18 June 20266 min read

Class 11 Basic Electrical Engineering — Exercise Solutions


Key Concepts Quick Recap

ConceptFormula / Value
Ohm's LawV = IR; I = V/R; R = V/I
PowerP = VI = I²R = V²/R (Watts)
EnergyE = Pt (Joules or kWh)
Series resistanceR_total = R₁ + R₂ + R₃
Parallel resistance1/R_total = 1/R₁ + 1/R₂ + 1/R₃
India AC supply230V (rms), 50 Hz, single phase
FuseSafety device; melts on excess current; in series with circuit

I. Choose the Best Answer (MCQs)

1. If V = 24V and R = 6Ω, the current I = (a) 2 A (b) 4 A (c) 6 A (d) 144 A

Answer(b) 4 A Ohm's Law: I = V/R = 24/6 = 4 A. Check: P = VI = 24 × 4 = 96 W. Also: P = I²R = 16 × 6 = 96 W. ✓

2. In a series circuit, the total resistance is: (a) Less than the smallest resistance (b) Equal to the sum of all individual resistances (c) Equal to the average of all resistances (d) Always 1 Ω

Answer(b) Equal to the sum of all individual resistances Series: R_total = R₁ + R₂ + ... (resistances add up). Current is same through all. Voltage divides. Parallel: 1/R_total = 1/R₁ + 1/R₂ + ... (total resistance is less than smallest). Voltage is same; current divides.

3. The unit of electrical power is: (a) Joule (b) Coulomb (c) Watt (d) Henry

Answer(c) Watt Power (P) = rate of doing work = VI = I²R = V²/R. Unit: Watt (W) = 1 Joule/second. Energy = Power × Time (Joules or kilowatt-hours, kWh). 1 kWh = 1000 W for 1 hour = 3.6 × 10⁶ J = 1 unit of electricity (for billing).

4. A fuse is connected: (a) In parallel with the load (b) In series with the circuit (c) Between the two live wires (d) After the load

Answer(b) In series with the circuit Fuse: protective device. Thin wire with low melting point; placed in series with circuit. When excess current flows → fuse wire melts → circuit breaks → protects equipment and wiring from damage. Rating should be slightly above normal operating current. MCB (Miniature Circuit Breaker) is modern alternative — auto-resets.

5. Transformer works on the principle of: (a) Mutual induction (b) Self-induction (c) Ohm's law (d) Coulomb's law

Answer(a) Mutual induction Transformer: AC electrical device; primary coil creates changing magnetic flux → induces EMF in secondary coil (mutual induction). Ratio: V₁/V₂ = N₁/N₂ = I₂/I₁. Step-up: N₂ > N₁; V₂ > V₁. Step-down: N₂ < N₁; V₂ < V₁. Only works with AC (DC gives no changing flux → no induction).

6. The resistance of two 6Ω resistors connected in parallel is: (a) 12 Ω (b) 6 Ω (c) 3 Ω (d) 1 Ω

Answer(c) 3 Ω Parallel: 1/R = 1/6 + 1/6 = 2/6 → R = 3 Ω. General rule for two equal resistors in parallel: R_total = R/2. For two unequal: R_total = (R₁ × R₂)/(R₁ + R₂).

7. The standard voltage supply to homes in India is: (a) 110V, 60 Hz (b) 230V, 50 Hz (c) 440V, 50 Hz (d) 220V, 60 Hz

Answer(b) 230V, 50 Hz India: 230V (rms), 50 Hz, single-phase domestic supply. Three-phase supply (for industrial/heavy loads): 415V (line-to-line), 50 Hz. US/Canada: 120V, 60 Hz (single phase). Most of Europe: 230V, 50 Hz (same as India).

II. Short Answer Questions

Q1. Explain the differences between series and parallel circuits with examples.
Answer

Series Circuit:

  • Components connected end-to-end in a single path.
  • Same current flows through all components.
  • Voltage divides across components (V = V₁ + V₂ + V₃).
  • R_total = R₁ + R₂ + R₃ (increases).
  • If one component fails → circuit breaks → all components stop working.
  • Example: old Christmas tree lights (one bulb fails → all go off).

Parallel Circuit:

  • Components connected with both ends joined to same two points.
  • Voltage is same across all components (same as supply voltage).
  • Current divides (I = I₁ + I₂ + I₃).
  • R_total = R₁R₂/(R₁+R₂) for two resistors (decreases with each added branch).
  • If one component fails → others continue working.
  • Example: household wiring (all appliances get 230V; one appliance off doesn't affect others).

Mixed (Series-Parallel): combination of both; solved by simplifying parallel sections first, then total.

Q2. What are the electrical safety precautions to be observed in a workplace?
Answer

Basic electrical safety rules:

1. Never work on live circuits: Always switch off and isolate (LOTO — Lock Out Tag Out) before working on electrical equipment.

2. Use insulated tools: Screwdrivers, pliers, wire cutters should have insulated handles rated for the voltage.

3. Don't overload circuits: Don't connect too many appliances to one socket/extension; check current rating.

4. Use proper fuses/MCBs: Correct rating for each circuit; never replace fuse with a higher-rated one or bypass it.

5. Earthing: All metal-bodied appliances must be properly earthed (third pin of plug). Earthing provides a low-resistance path for fault current → trips fuse/MCB → protects users.

6. Moisture and electricity: Never use electrical equipment with wet hands; keep water away from electrical fittings.

7. Cable management: No frayed or damaged cables; avoid running cables under carpets or through walls without proper conduit.

8. Fire safety: Know location of fire extinguisher (CO₂ type for electrical fires — NOT water).


Exam Checklist

  • Ohm's Law: V = IR; I = V/R; R = V/I.
  • Power: P = VI = I²R = V²/R (Watts). Energy = P × t (kWh).
  • Series: R adds; same I; voltage divides.
  • Parallel: R reduces; same V; current divides.
  • Fuse: in series; melts on excess current.
  • Transformer: mutual induction; V₁/V₂ = N₁/N₂.
  • India: 230V, 50 Hz domestic supply.
  • Safety: LOTO, earthing, insulated tools, CO₂ fire extinguisher for electrical fires.

Frequently Asked Questions

Ohm's Law (Georg Simon Ohm, 1827): The current (I) through a conductor is directly proportional to the potential difference (V) across it, provided temperature and other physical conditions remain constant. Formula: V = IR (or I = V/R; R = V/I). Units: V = Volts, I = Amperes, R = Ohms (Ω). Applications: circuit design, calculating unknown quantities (V, I, or R), selecting appropriate resistors, fuses. Limitations: does not apply to non-linear elements (diodes, transistors, thyristors) which have non-constant resistance.
← Browse all Class 11 Exercise Solutions